The sizes detailed below are for guidance only, maximum widths can vary depending on your chosen height and vice versa. If the sizes you require are less than the minimum or exceed our maximum recommended sizes please ask our technical department for advice.
The Sizes Below Apply For Single; Front Doors and Back Doors
Single Doors - Recommended Sizes | |
---|---|
Min. Width (mm) | 600 |
Max. Width (mm) | 1000 |
Min. Height (mm) | 1700 |
Max. Height (mm) | 2400 |
Max. Panel Width (mm) | 900 |
Max. Sash Weight (Kg) | 80 |
Single Doors - Sight Lines | |
---|---|
Head / Top (mm) | 110 |
Jamb / Side (mm) | 110 |
Meeting Stiles (mm) | N/A |
Bottom - Std Threshold (mm) | 110 |
Std Threshold (mm) | 46 |
Low Thresholds (mm) | 13 |
The Sizes Below Apply For Double; Front Doors / Back Doors / French Doors
Double Doors - Recommended Sizes | |
---|---|
Min. Width (mm) | 1200 |
Max. Width (mm) | 2000 |
Min. Height (mm) | 1700 |
Max. Height (mm) | 2400 |
Max. Panel Width (mm) | 900 |
Max. Sash Weight (Kg) | 80 |
Double Doors - Sight Lines | |
---|---|
Head / Top (mm) | 110 |
Jamb / Side (mm) | 110 |
Meeting Stiles (mm) | 167 |
Bottom - Std Threshold (mm) | 110 |
Std Threshold Height (mm) | 46 |
Low Thresholds Height (mm) | 13 |
See Section Identifications for more information and detailed technical drawings.
Entrance Door Performance | |
---|---|
Complies
Regulations 600 Pa
Air
Permeable 250 Pa
Water
Tightness 1200 Pa
Wind
Resistance These statistics apply for: |
Specifying - Suitable Applications | |
---|---|
|
Technical Downloads | |
---|---|
(Open in weather tested to BS EN 1026, BS EN 1027, BS EN 12211) | 0.3 Mb |
AutoCAD Drawings - Downloads |
---|
Technical drawings can be provided in DWG or DXF format, please contact us. |
Downloads Not Working? |
---|
If you are having problems downloading documents from our website please be patient as it may take a few minutes. Make sure you have the latest version of Adobe Reader - you can download Adobe Reader here for free. Alternatively we can send you the file by email - contact us. |
Sight Lines | |
---|---|
Outerframe Depth (mm) 1 | 47 or 70 |
Sash Depth (mm) | 47 |
Glazed Sealed Units (mm) | 28 (4 x 20 x 4) |
Projection Cill Height - Optional (mm) | 25 |
Head Extension - if required (mm) 2 | 20 or 32 |
Midrail - if required (mm) | 109 |
Coupling Bar - if required (mm) | 35.5 |
This site uses cookies and other tracking technologies to assist with navigation and your ability to provide feedback, analyse your use of our products and services, assist with our promotional and marketing efforts, and provide content from third parties. Cookie Policy